Previous revision
battery_compatibility:exide [2022-07-18 12:52] – [4. VEConfigure settings] iburgerbattery_compatibility:exide [2022-08-15 13:45] (current) dfaber
Line 1: Line 1:
-====== DRAFT: Victron & Exide =====+====== Victron & Exide ===== 
 + 
 +**This combination depends on Venus OS v2.90 or above, which is scheduled to be released later in 2022. Or the latest beta (see [[ccgx:beta-testing|]]).**
  
 The combination of Victron products with the Exide battery has been tested and certified by the R&D departments. The combination is actively supported by both companies.  The combination of Victron products with the Exide battery has been tested and certified by the R&D departments. The combination is actively supported by both companies. 
  
 Compatible models: Compatible models:
-  * LIBM0480050-G01 as of firmware v1.10+  * Sonnenschein Module Pro LIBM0480050-G01 as of firmware v1.10 
 + 
 +{{:battery_compatibility:exide.png?nolink&400|}}
  
 ==== 1. Introduction ==== ==== 1. Introduction ====
Line 11: Line 15:
 === 1.1 Compatible Victron products === === 1.1 Compatible Victron products ===
 All 48V Multis and Quattros. And always a [[venus-os:start|GX device]] is necessary in the system, since that has the canbus port which is used for the (required!) communication between the ESS battery and the Victron system. All 48V Multis and Quattros. And always a [[venus-os:start|GX device]] is necessary in the system, since that has the canbus port which is used for the (required!) communication between the ESS battery and the Victron system.
- 
-=== 1.2 Notes === 
- 
-=== 1.3 System diagram === 
  
 ==== 2. GX device needed ==== ==== 2. GX device needed ====
Line 20: Line 20:
  
 ==== 3. Wiring of communication cables ==== ==== 3. Wiring of communication cables ====
-Use the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018. Plug the side which is labeled Battery BMS into the Exide BMSPlug the side labeled Victron VE.Can into the [[venus-os:start|GX device]].+A cable for the CAN-bus connection ships with the batteryThis cable has only CAN-L and CAN-H connections and no ground wireThe side of the cable with pins 7 and 8 should be plugged into the 
 +[[venus-os:start|GX device]], and the side with pins 1 (CAN-L) and 2 (CAN-H) goes to the battery.
  
 Exide batteries come with a CAN-bus terminator already installed/supplied. When assembling the battery from individual modules, remember to terminate the CAN-bus on the last module, using the supplied terminator. In most cases, this is already done in the factory. Exide batteries come with a CAN-bus terminator already installed/supplied. When assembling the battery from individual modules, remember to terminate the CAN-bus on the last module, using the supplied terminator. In most cases, this is already done in the factory.
- 
-More information about the cable can be found in [[battery_compatibility:can-bus_bms-cable|here]]. 
  
 Without properly connecting this cable, the battery will stop charging/discharging after several minutes. Also, the battery will not show up on the display of the [[venus-os:start|GX device]]. Without properly connecting this cable, the battery will stop charging/discharging after several minutes. Also, the battery will not show up on the display of the [[venus-os:start|GX device]].
Line 79: Line 78:
  
   * After properly wiring and setting up, the Exide ESS will be visible as a battery in the device list:{{ :battery_compatibility:exide_battery_menu.png?nolink&290 | }}   * After properly wiring and setting up, the Exide ESS will be visible as a battery in the device list:{{ :battery_compatibility:exide_battery_menu.png?nolink&290 | }}
-  * The parameters option within the battery page shows the actual battery charge and discharge limits:{{ :battery_compatibility:batteryparameters.png?nolink&290 | }}+  * The parameters option within the battery page shows the actual battery charge and discharge limits:{{ :battery_compatibility:exide_parameters.png?nolink&290 |}} 
 + 
 +Next, go to Settings, DVCC, and configure as follows:
  
 +^Venus Settings -> System Setup Parameter ^ Value ^ 
 +|DVCC|ON|
 +|Shared Voltage Sense |OFF| 
 +|Shared Temperature Sense |OFF|
 ===== 6. MPPT Settings ===== ===== 6. MPPT Settings =====
  